Effect of filter type in ventilation systems on NO2 concentrations in classrooms
This study was conducted to assess how different filter types in the ventilation system affect the indoor NO2 concentrations. Measurements were carried out in two classrooms and air intakes in a primary school located in Oslo, Norway. A regular F7 particle filter and an F7 combination filter with activated charcoal lin-ing were compared. NO2 concentrations were measured for five weeks during winter 2017 in a cross-over study design to compare: 1) NO2-levels in classrooms with regular filter (RF) versus combination filter (CF); 2) indoor/outdoor ratio with regular filter versus combination filter. One-hour average concentrations are reported during operating time of the ventilation system (6:00-23:00) and during hours with high (> 40 μg/m3) outdoor NO2 concentrations. The measured average NO2 concentrations in both classrooms with an RF were significantly higher than with a CF. The median CF/RF ratios for the two class-rooms were 0.50 and 0.81 during hours with high NO2 concentrations, and 0.48 and 1.00 during the period the ventilation system was operational. During hours with high NO2 concentrations, themedian indoor/outdoor ratios for the two class-rooms with an RF were above 1.00, while the corresponding ratios with a CF were 0.78 and 0.75. Our results demonstrate that a combination filter is more efficient than a regular filter in reducing NO2 concentrations in classrooms during hours with high out-door concentrations.
2019
2019
Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
<p>Monitoring air pollution is a critical step towards improving public health, particularly when it comes to identifying the primary air pollutants that can have an impact on human health. Among these pollutants, particulate matter (PM) with a diameter of up to 2.5 μm (or PM2.5) is of particular concern, making it important to continuously and accurately monitor pollution related to PM. The emergence of mobile low-cost PM sensors has made it possible to monitor PM levels continuously in a greater number of locations. However, the accuracy of mobile low-cost PM sensors is often questionable as it depends on geographical factors such as local atmospheric conditions. <p>This paper presents new calibration methods for mobile low-cost PM sensors that can correct inaccurate measurements from the sensors in real-time. Our new methods leverage Neural Architecture Search (NAS) to improve the accuracy and efficiency of calibration models for mobile low-cost PM sensors. The experimental evaluation shows that the new methods reduce accuracy error by more than 26% compared with the state-of-the-art methods. Moreover, the new methods are lightweight, taking less than 2.5 ms to correct each PM measurement on Intel Neural Compute Stick 2, an AI-accelerator for edge devices deployed in air pollution monitoring platforms.
2023
2024
2025
2018
2018
2024
2018
2018
2023
2024