Gå til innhold
  • Send

  • Kategori

  • Sorter etter

  • Antall per side

Fant 2682 publikasjoner. Viser side 76 av 269:

Publikasjon  
År  
Kategori

Impact of synthetic space-borne NO2 observations from the Sentinel-4 and Sentinel-5P missions on tropospheric NO2 analyses

Timmermans, Renske; Segers, Arjo; Curier, Lyana; Abida, Rachid; Attié, Jean-Luc; Amraoui, Laaziz El; Eskes, Henk; Haan, Johan de; Kujanpää, Jukka; Lahoz, William A.; Nijhuis, Albert Oude; Quesada-Ruiz, Samuel; Ricaud, Philippe; Veefkind, Pepijn; Schaap, Martijn

We present an Observing System Simulation Experiment (OSSE) dedicated to the evaluation of the added value of the Sentinel-4 and Sentinel-5P missions for tropospheric nitrogen dioxide (NO2). Sentinel-4 is a geostationary (GEO) mission covering the European continent, providing observations with high temporal resolution (hourly). Sentinel-5P is a low Earth orbit (LEO) mission providing daily observations with a global coverage. The OSSE experiment has been carefully designed, with separate models for the simulation of observations and for the assimilation experiments and with conservative estimates of the total observation uncertainties. In the experiment we simulate Sentinel-4 and Sentinel-5P tropospheric NO2 columns and surface ozone concentrations at 7 by 7 km resolution over Europe for two 3-month summer and winter periods. The synthetic observations are based on a nature run (NR) from a chemistry transport model (MOCAGE) and error estimates using instrument characteristics. We assimilate the simulated observations into a chemistry transport model (LOTOS-EUROS) independent of the NR to evaluate their impact on modelled NO2 tropospheric columns and surface concentrations. The results are compared to an operational system where only ground-based ozone observations are ingested. Both instruments have an added value to analysed NO2 columns and surface values, reflected in decreased biases and improved correlations. The Sentinel-4 NO2 observations with hourly temporal resolution benefit modelled NO2 analyses throughout the entire day where the daily Sentinel-5P NO2 observations have a slightly lower impact that lasts up to 3–6 h after overpass. The evaluated benefits may be even higher in reality as the applied error estimates were shown to be higher than actual errors in the now operational Sentinel-5P NO2 products. We show that an accurate representation of the NO2 profile is crucial for the benefit of the column observations on surface values. The results support the need for having a combination of GEO and LEO missions for NO2 analyses in view of the complementary benefits of hourly temporal resolution (GEO, Sentinel-4) and global coverage (LEO, Sentinel-5P).

2019

Source apportionment to support air quality planning: Strengths and weaknesses of existing approaches

Thunis, Philippe; Clappier, A.; Tarrasón, Leonor; Cuvelier, Cornelis; Monteiro, Ana; Pisoni, Enrico; Wesseling, Joost; Belis, Claudio A.; Pirovano, Guido; Janssen, Stijn; Guerreiro, Cristina; Peduzzi, Emanuela

Information on the origin of pollution constitutes an essential step of air quality management as it helps identifying measures to control air pollution. In this work, we review the most widely used source-apportionment methods for air quality management. Using theoretical and real-case datasets we study the differences among these methods and explain why they result in very different conclusions to support air quality planning. These differences are a consequence of the intrinsic assumptions that underpin the different methodologies and determine/limit their range of applicability. We show that ignoring their underlying assumptions is a risk for efficient/successful air quality management as these methods are sometimes used beyond their scope and range of applicability. The simplest approach based on increments (incremental approach) is often not suitable to support air quality planning. Contributions obtained through mass-transfer methods (receptor models or tagging approaches built in air quality models) are appropriate to support planning but only for specific pollutants. Impacts obtained via “brute-force” methods are the best suited but it is important to assess carefully their application range to make sure they reproduce correctly the prevailing chemical regimes.

2019

Performance assessment of a low-cost PM2.5 Sensor for a near four-month period in Oslo, Norway

Liu, Hai-Ying; Schneider, Philipp; Haugen, Rolf; Vogt, Matthias

The very low-cost Nova particulate matter (PM) sensor SDS011 has recently drawn attention for its use for measuring PM mass concentration, which is frequently used as an indicator of air quality. However, this sensor has not been thoroughly evaluated in real-world conditions and its data quality is not well documented. In this study, three SDS011 sensors were evaluated by co-locating them at an official, air quality monitoring station equipped with reference-equivalent instrumentation in Oslo, Norway. The sensors’ measurement results for PM2.5 were compared with data generated from the air quality monitoring station over almost a four-month period. Five performance aspects of the sensors were examined: operational data coverage, linearity of response and accuracy, inter-sensor variability, dependence on relative humidity (RH) and temperature (T), and potential improvement of sensor accuracy, by data calibration using a machine-learning method. The results of the study are: (i) the three sensors provide quite similar results, with inter-sensor correlations exhibiting R values higher than 0.97; (ii) all three sensors demonstrate quite high linearity against officially measured concentrations of PM2.5, with R2 values ranging from 0.55 to 0.71; (iii) high RH (over 80%) negatively affected the sensor response; (iv) data calibration using only the RH and T recorded directly at the three sensors increased the R2 value from 0.71 to 0.80, 068 to 0.79, and 0.55 to 0.76. The results demonstrate the general feasibility of using these low cost SDS011 sensors for indicative PM2.5 monitoring under certain environmental conditions. Within these constraints, they further indicate that there is potential for deploying large networks of such devices, due to the sensors’ relative accuracy, size and cost. This opens up a wide variety of applications, such as high-resolution air quality mapping and personalized air quality information services. However, it should be noted that the sensors exhibit often very high relative errors for hourly values and that there is a high potential of abusing these types of sensors if they are applied outside the manufacturer-provided specifications particularly regarding relative humidity. Furthermore, our analysis covers only a relatively short time period and it is desirable to carry out longer-term studies covering a wider range of meteorological conditions

2019

White-Tailed Eagle (Haliaeetus albicilla) Body Feathers Document Spatiotemporal Trends of Perfluoroalkyl Substances in the Northern Environment

Sun, Jiachen; Bossi, Rossana; Bustnes, Jan Ove; Helander, Björn; Boertmann, David; Dietz, Rune; Herzke, Dorte; Jaspers, Veerle; Labansen, Aili Lage; Lepoint, Gilles; Schulz, Ralf; Sonne, Christian; Thorup, Kasper; Tøttrup, Anders; Zubrod, Jochen P.; Eens, Marcel; Eulaers, Igor

2019

The comet assay applied to HepG2 liver spheroids

Elje, Elisabeth; Hesler, Michelle; Rundén-Pran, Elise; Mann, Pascal; Mariussen, Espen; Wagner, Sylvia; Dusinska, Maria; Kohl, Yvonne

In accordance with the 3 Rs to reduce in vivo testing, more advanced in vitro models, moving from 2D monolayer to 3D cultures, should be developed for prediction of human toxicity of industrial chemicals and environmental pollutants. In this study we compared cytotoxic and genotoxic responses induced by chemicals in 2D and 3D spheroidal cultures of the human liver cancer cell line HepG2.

HepG2 spheroids were prepared by hanging drop technology. Both 3D spheroids and 2D monolayer cultures were exposed to different chemicals (colchicine, chlorpromazine hydrochloride or methyl methanesulfonate) for geno- and cytotoxicity studies. Cytotoxicity was investigated by alamarBlue assay, flow cytometry and confocal imaging. DNA damage was investigated by the comet assay with and without Fpg enzyme for detection of DNA strand breaks and oxidized or alkylated base lesions.

The results from the cyto- and genotoxicity tests showed differences in sensitivity comparing the 2D and 3D HepG2 models. This study shows that human 3D spheroidal hepatocellular cultures can be successfully applied for genotoxicity testing by the comet assay and represent a promising advanced in vitro model for toxicity testing.

2019

DNA double‐strand breaks in Arctic char (Salvelinus alpinus) from Bjørnøya in the Norwegian Arctic

Neerland, Eirik D.; Bytingsvik, Jenny; Nikiforov, Vladimir; Evenset, Anita; Krøkje, Åse

High levels of organochlorine contaminants (OCs) have been found in arctic char (Salvelinus alpinus) from Lake Ellasjøen, Bjørnøya (Norwegian Arctic). The aim of the present study was to investigate the potential genotoxic effect of environmental organochlorine contaminant exposure in arctic char from Ellasjøen compared with arctic char from the low‐contaminated Lake Laksvatn nearby. Blood was analyzed using agarose gel electrophoresis and image data analysis to quantify the fraction of total DNA that migrated into the gel (DNA‐FTM) as a relative measure of DNA double‐strand breaks (DSBs). Analysis by GC‐MS of muscle samples showed an average 43 times higher concentration of ΣOCs in arctic char from Ellasjøen (n = 18) compared with Laksvatn char (n = 21). Char from Lake Ellasjøen had a much higher frequency of DSBs, as measured by DNA‐FTM, than char from Lake Laksvatn. Principal component analysis and multiple linear regressions show that there was a significant positive relationship between DSBs and levels of organochlorine contaminants in the char. In addition, DSBs were less frequent in reproductively mature char than in immature char. The results suggest that organochlorine contaminants are genotoxic to arctic char.

2019

The strength in numbers: comprehensive characterization of house dust using complementary mass spectrometric techniques

Rostkowski, Pawel; Haglund, Peter; Aalizadeh, Reza; Alygizakis, Nikiforos; Thomaidis, Nikolaos; Arandes, Joaquin Beltran; Bohlin-Nizzetto, Pernilla; Booij, Petra; Budzinski, Hélène; Brunswick, Pamela; Covaci, Adrian; Gallampois, Christine; Grosse, Sylvia; Hindle, Ralph; Ipolyi, Ildiko; Jobst, Karl; Kaserzon, Sarit; Leonards, Pim; Lestremau, Francois; Letzel, Thomas; Magnér, Jörgen; Matsukami, Hidenori; Moschet, Christoph; Oswald, Peter; Plassmann, Merle; Slobodnik, Jaroslav; Yang, Chun

Untargeted analysis of a composite house dust sample has been performed as part of a collaborative effort to evaluate the progress in the field of suspect and nontarget screening and build an extensive database of organic indoor environment contaminants. Twenty-one participants reported results that were curated by the organizers of the collaborative trial. In total, nearly 2350 compounds were identified (18%) or tentatively identified (25% at confidence level 2 and 58% at confidence level 3), making the collaborative trial a success. However, a relatively small share (37%) of all compounds were reported by more than one participant, which shows that there is plenty of room for improvement in the field of suspect and nontarget screening. An even a smaller share (5%) of the total number of compounds were detected using both liquid chromatography–mass spectrometry (LC-MS) and gas chromatography–mass spectrometry (GC-MS). Thus, the two MS techniques are highly complementary. Most of the compounds were detected using LC with electrospray ionization (ESI) MS and comprehensive 2D GC (GC×GC) with atmospheric pressure chemical ionization (APCI) and electron ionization (EI), respectively. Collectively, the three techniques accounted for more than 75% of the reported compounds. Glycols, pharmaceuticals, pesticides, and various biogenic compounds dominated among the compounds reported by LC-MS participants, while hydrocarbons, hydrocarbon derivatives, and chlorinated paraffins and chlorinated biphenyls were primarily reported by GC-MS participants. Plastics additives, flavor and fragrances, and personal care products were reported by both LC-MS and GC-MS participants. It was concluded that the use of multiple analytical techniques was required for a comprehensive characterization of house dust contaminants. Further, several recommendations are given for improved suspect and nontarget screening of house dust and other indoor environment samples, including the use of open-source data processing tools. One of the tools allowed provisional identification of almost 500 compounds that had not been reported by participants.

2019

Global soil nitrous oxide emissions since the preindustrial era estimated by an ensemble of terrestrial biosphere models: Magnitude, attribution, and uncertainty

Tian, Hanqin; Yang, Jia; Xu, Rongting; Lu, Chaoqun; Canadell, Josep G.; Davidson, Eric A.; Jackson, Robert B.; Arneth, Almut; Chang, Jinfeng; Ciais, Philippe; Gerber, Stefan; Ito, Akihiko; Joos, Fortunat; Lienert, Sebastian; Messina, Palmira; Olin, Stefan; Pan, Shufen; Peng, Changhui; Saikawa, Eri; Thompson, Rona Louise; Vuichard, Nicolas; Winiwarter, Wilfried; Zaehle, Sönke; Zhang, Bowen

2019

Publikasjon
År
Kategori